Energy Saving Products Available Internationally
High Efficiency Variable Speed Heat Pumps
 

Model HE-040/220 HE-070/220
    Outdoor Unit Tonnage 10.5 kW (3 Ton) 17 kW (5 Ton)
    Part Number 50180400003 50180400005
Capacity Data
    Nominal Cooling Capacity 10.4kW (35,500 BTU)

16.8kW (57,300 BTU)

    Operational Range (Cooling) 2.6-10.5kW (9,000-36,000 BTU)

4.4-17.6kW (15,000-60,000 BTU)

    Nominal Heating Capacity 11.2kW (38,200 BTU)

17.7kW (60,400 BTU)

    Operational Range (Heating) 3.5 -13.9kW (11,800-47,400 BTU)

5.5-22kW (18,700-75,000 BTU)

    Highest Variable Airflow (l/S) 849 l/s  (1,800 CFM)

1,038 l/s  (2,200 CFM)

    Lowest Variable Airflow 189 l/s (400 CFM)

189 l/s (400 CFM)

     Power Supply 220 Volts-1Phase-50/60 Hz

220 Volts-1Phase-50/60 Hz

     Nom. Full Load Amps 22

30

     Min. Circuit Size (Amps) 35

36

     Electrical Input Cooling (kW) 3.25

5.3

     Electrical Input Heating (kW) 3.15

5.2

    ACOP 3.5

3.38

    SEER Up to 18

Up to 18

Sound Pressure(dB)(A)@1m 62

63

Soft Starter Variable Frequency

Variable Frequency

Length 96.5 cm (38")

95.3 cm (37.5")

Width 41 cm (16.14")

41.3 cm (16.25")

Height 81.3 cm (32")

133.4 cm (52.5")

Weight 70.3 kg (155 lbs)

122 kg (269 lbs)

  DESIGN CONDITIONS:
Cooling 35°C (95°F) DB Outdoor / 27°C (80°F) DB, 19°C (66°F) WB Air Entering Indoor Unit
Heating 7°C (44°F)DB, 6°C (43°F) WB Outdoor/ 21°C (70°F) DB Air Entering Indoor Unit
Nominal Operating Range -10°C (14°F) WB to 50°C (122°F) DB
Sound pressure level is influenced by the surroundings, therefore it may vary upon location.